106/118
T24 System Manual Part 2: System Restore
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
5.2.4 Exchanging T24-Info2wire+ Components
The T24’s two-wire cabeling set always consists of two devices:
the outdoor station’s T24-Info2wire+ info module and a second
indoor unit installed inside the building.
When you exchange them, the door station’s power supply is
disconnected automatically. The door station is automatically
ready for operation again once the power supply has been
reconnected. A system restore is not required.
Proceed As Follows:
1. Disconnect the door station and T24-Info2wire+ com
-
ponents from the power supply.
2.
Remove the T24-Info2wire+ info module to be exchanged
from the module frame as described in the T24 System
Manual Part 1/Section 2.4.6 (Removing And Exchanging Modules).
3. Exchange the old info module and indoor unit with the new devices. Take care not
to damage the cabling or mix up the connections. The connection diagrams are
provided in the T24 System Manual Part 1.
4. Power up the system again. After an automatic reboot, the door station is ready
for operation again.
Notes
The two T24-Info2wire+ units are matching pairs and preconfigured at the factory.
Matched units share the same network ID (see labels on the back of the info module
and on the indoor unit’s circuit board). In case of a defect, both units must always be
exchanged for a new Mx2wire pair that has been configured by MOBOTIX and shipped
in its original packaging.